Engineering
Engineering, 11.07.2019 02:20, vkrizh

Aroom in a house is maintained at 25 °c by a heat pump. the air outside is at 9 °c. heat is being lost out a 4.5 mm thick single-pane window which is 0.5 m high by 1 m wide. if the heat transfer coefficients at the inside and outside surfaces of the window are 12 and 30 w m-2 k-1 respectively and the thermal conductivity of the window glass is 0.78 w m k-1, calculate the rate of heat loss through the window.

answer
Answers: 1

Other questions on the subject: Engineering

image
Engineering, 04.07.2019 18:10, niyawilliams23
Asingle-geared blanking press has a stroke of 200 mm and a rated capacity of 320 kn. a cam driven ram is assumed to be capable of delivering the full press load at constant force during the last 15 percent of a constant-velocity stroke. the camshaft has an average speed of 90 rev/min and is geared to the flywheel shaft at a 6: 1 ratio. the total work done is to include an allowance of 16 percent for friction a) estimate the maximum energy fluctuation b) find the rim weight for an effective diameter of 1.2 m and a coefficient of speed fluctuation of 0.10
Answers: 1
image
Engineering, 04.07.2019 18:10, meganwintergirl
Afour cylinder four-stroke in-line engine has a stroke of 160mm, connecting rod length of 150mm, a reciprocating mass of 3kg and its firing order is 1-3-4-2. the spacing between cylinders is 100mm. i. show that the engine is in balance with regard to the primary inertia forces and primary 3. a and secondary inertia couples. li determine the out of balance secondary inertia force ii. propose ways of balancing this out of balance force and discuss the challenges that will arise
Answers: 3
image
Engineering, 04.07.2019 18:20, xcapo1x
Refrigerant-134a enters the compressor of a refrigerator as superheated vapor at 0.14 mpa and -10°c at a rate of 0.05 ka/s and leaves at 0.8 mpa and 50°c. the refrigerant is cooied in the condenser to 0.72 mpa and 26'c. it is then throttled to 0.15 mpa. sketch the t-s diagram for the system and evaluate: 6) the rate of heat removai from the refrigerated space (kw), it) the power input to the compressor (kw), ii) the isentropic efficiency of the compressor (%), and iv) the cop of the refrigerator.
Answers: 2
image
Engineering, 04.07.2019 19:10, babas97
What is a monomer? how do they form a ploymer from the view point of chemical bonding?
Answers: 1
Do you know the correct answer?
Aroom in a house is maintained at 25 °c by a heat pump. the air outside is at 9 °c. heat is being lo...

Questions in other subjects:

Konu
English, 23.10.2020 19:20
Konu
Mathematics, 23.10.2020 19:20
Konu
Chemistry, 23.10.2020 19:20
Konu
Biology, 23.10.2020 19:20