Engineering
Engineering, 04.07.2019 18:10, oshawn108

Ahot wire operates at a temperature of 200°c while the air temperature is 20°c. the hot wire element is a tungsten wire of 5 um diameter and 2 mm in length. plot using excel current, heat transfer and heat generated by the wire for air velocity varying from 1-10 m/s in steps of lm/s? matlab the sensor voltage output, resistance, or assume nu 0.989 re033pr13 take air properties at tr (200°c20°c)/2 = 110°c properties of tungsten: c 0.13 kj/kg. k 3 p 19250 kg/m k (thermal conductivity) = 174 w/m. k

answer
Answers: 2

Other questions on the subject: Engineering

image
Engineering, 04.07.2019 19:20, horsedoggal1234
Consider airflow over a flat plate of length l = 1.5 m under conditions for which transition occurs at le = 0.9 m based on the critical reynolds number, re, e = 5 x 10. evaluating the thermophysical properties of air at 400 k, determine the air velocity. (hint: use the tables to find the properties of air)
Answers: 3
image
Engineering, 05.07.2019 04:30, kookycookiefanx
Technician a says that in a worm gear steering system, most excessive steering free play is usually found in the gearbox. technician b says that in a rack-and-pinion steering system, excessive free play can be found in the bushings. who is correct?
Answers: 2
image
Engineering, 06.07.2019 04:10, nickmoose04
Aheat pump with refrigerant-134a as the working fluid is used to keep a space at 25°c by absorbing heat from geothermal water that enters the evaporator at 500c at a rate of 0.065 kg/s and leaves at 40°c. the refrigerant enters the evaporator at 20°c with a quality of 23 percent and leaves at the inlet pressure as saturated vapor. the refrigerant loses 300 w of heat to the surroundings as it flows through the compressor and the refrigerant leaves the compressor at 1.4 mpa at the same entropy as the inlet. determine: (a) the degrees of subcooling of the refrigerant in the condenser, b)-the mass flow rate of the refrigerant . (c) the heating load and the cop of the pump, and d)-the theoretical minimum power input to the compressor for the same heating load.
Answers: 3
image
Engineering, 06.07.2019 04:30, alyssa0888
Asharp-edged orifice is placed in a 10-in-diameter pipe carrying ammonia. if the volume flow rate is 25 gal/min, calculate the deflection of a water manometer (a) if the orifice diameter is 1.0 in and (b) if the orifice diameter is 7.0 in. the ammonia has a specific gravity of 0.83 and a dynamic viscosity of 2.5 x 10-6 lb s/t2
Answers: 3
Do you know the correct answer?
Ahot wire operates at a temperature of 200°c while the air temperature is 20°c. the hot wire element...

Questions in other subjects:

Konu
Arts, 13.02.2021 07:20