Computers and Technology
Computers and Technology, 24.03.2021 19:30, mkcryer50

Assume a single standard three stage (load, execute, write back) functional unit. Also assume that the execution (stage 2) of multiplication requires 3 units of time, subtraction requires 2 units of time, and addition requires 1 unit of time. Stages 1 and 3 require 1 unit of time. If the computer can perform instruction level parallelism, then how many units of time are there when an instruction is stalled in stage 1? A stall is when an instruction has ENTERED and COMPLETED stage 1, but is not able to leave stage 1 because stage 2 is occupied. Do NOT count the 1 unit of time that an instruction spends in stage 1 while the operands are loaded.
type function2(type a, type b, type c, type d){
type var1 = a - b;
type var2 = var1 * c;
type var3 = a + d;
return var3;
}

answer
Answers: 2

Other questions on the subject: Computers and Technology

image
Computers and Technology, 22.06.2019 03:30, raytaylorh010801
Write a computer program to calculate the three-phase fault current for a fault at f in figure 1.16, with the network normal, and with one line at a time removedproblems 1.1 write a computer program to calculate the three-phase fault current for a fault at f in figure 1.16, with the network normal, and with one line at a time removed 20 power system relaying from service. the positive-sequence impedance data are given in the accompanying table. use the commonly made assumption that all prefault resistance values are (1.0+j0.0) pu, and neglect all resistance values. calculate the contribution to the fault flowing through the cb b and the voltage at that bus. for each calculated case, consider the two possibilities: cb b2 closed or open. the latter is known as the stub-end fault í• figure 1.16 problem 1.1 system data for figure 1.16 from to positive sequence 0.0+j0.1 0.05j0.15 0.04 j0.2 0.01 jo. i 0.015 + j0.15 0.01 j0.19 0.01 +j0.19 0.03+j0.1 0.0+j0.08 6 6 6 from service. the positive-sequence impedance data are given in the accompanying table. use the commonly made assumption that all prefault resistance values are (1.0 + j 0.0) pu, and neglect all resistance values. calculate the contribution to the fault flowing through the cb b1, and the voltage at that bus. for each calculated case, consider the two possibilities: cb b2 closed or open. the latter is known as the “stub-end” fault.
Answers: 2
image
Computers and Technology, 22.06.2019 23:30, keviongardner
The next button in the review section shows the next available comment. next slide with no comment. previous comment. edited comment.
Answers: 1
image
Computers and Technology, 23.06.2019 21:30, maddietomlinson113
Examine the list below. which factors positively affect lifetime income? check all that apply.
Answers: 1
image
Computers and Technology, 24.06.2019 00:10, roxymiller3942
Read each statement below. if the statement describes a peer-to-peer network, put a p next to it. if the statement describes a server-based network, put an s next to it. p - peer-to-peer s - server-based
Answers: 1
Do you know the correct answer?
Assume a single standard three stage (load, execute, write back) functional unit. Also assume that t...